| Specifications
Physical
Size:
9.25 x 7.13 x 4.0 in (235 x 181 x 102mm)
Weight:
7.5lbs. (3,4Kgs) with Li-Ion cells.
Case: Extruded Aluminum.
Display: Transflective
TFT Color. Display area: 4.39” x
3.29” (111.4 x 83.5mm) 320 x 240
pixels. A-Scan area: 255 x 200 pixels
(315 x 200 expanded), 8 color options
and variable brightness.
Temperature:
Operating –10 to +55°C or 14
to 131°F
–20 to +70°C or –4 to
158°F
(survivable)
Storage –40 to +75°C or –40
to 167°F
Environmental:
Meets IP65 requirements.
Specifications
Units: English (inch),
Metric (mm), or Time (µs).
Probe Zero: 0–999.999
µs.
Velocity: 615
& 625 0.0393 to 0.3937
in/µs (1000–9999m/s). 635
& 638 0.0100 in/µs
(256 to 16000 m/s.
Test Range: 615
& 625 0 - 0.2in (5mm)
up to 0 - 400in (10,000mm) at steel velocity.
Variable in sequence, 0.4in or 0.04in
(10mm or 1mm). 635
& 638 0 - 0.05in (1mm)
up to 0 - 800in (20,000mm) at steel velocity.
Variable in 1, 2, 5 sequence or continuously
in 0.05in (1mm) increments. Also from
1 to 5000(µs).
Test Modes: Pulse-echo
and transmit/receive.
Gates: 615
& 625 Start &
Width adjustable over full range. Amplitude
0 -100%, 0.5% steps. Visual & audible
alarms. Single gate positive trigger,
and two gates positive and negative triggering.
Gate 2 has selectable 0.6 second delay
on alarm. 635
& 638 Two fully independent
gates with positive and negative triggering
for each gate.
Gate Expansion:
635 &
638 Expands range to width
of Gate 1.
Gate Monitor Delay:
635 &
638 Selectable 0.6 sec
delay on gate 2 negative monitor.
Measurement Modes:
Signal Monitor - 635
& 638
Depth - Depth and amplitude
of signal in gate.
Echo Echo - Echo-Echo
distance, automatic gate 2 position.
Gate to Gate -
625:
Echo-Echo distance , manual gate 2 position.
635 &
638 independent gates. |
Trig - Trigonometric
display of beam path, depth and surface
distance. Calculation of skip depth and
curve surface compensation, X-offset for
transducer.
T-Min - Holds minimum
thickness in depth mode.
System Linearity: Vertical
= 1% Full Screen Height (FSH) Amplifier
Accuracy ±0.1%dB. Horizontal ±0.4%
Full Screen Width (FSW).
Pulser Voltage: 615
& 625 200 volt peak
amplitude, rise/fall time < 10ns into
50ohm. 635
& 638 100V - 350V
(450V 638 ) square wave pulser. Pulse
width from spike to 2000ns duration -
rise/fall times < 5ns into 50 ohms.
Pulser Width: 615
fixed at 100ns. 625
30-250ns linked to filter
band. 635
& 638 Adjustable in
2% of nominal width, minimum 1ns maximum
40ns.
ActiveEdge: Unique active
pulse control for enhanced near surface
resolution and signal response. Replaces
traditional damping control.
P.R.F.: 615
& 625 Selectable 35
to 1000Hz (635
& 638 5000Hz), 5Hz
steps.
Screen Update Rate:
50 or 60Hz.
Rectification: Full
wave, positive or negative half wave and
unrectified RF.
Delay: 615
& 625 0 - 400 in (10,000mm)
635 &
638 0 - 800in (20,000mm)
at steel velocity in 0.02 steps (0.05mm).
Gain: 0 to 110dB.
Adjustable in 0.5, 2, 6, 14 and 20dB steps.
Frequency Bands:
615:
Broadband 1 - 10 MHz (-6dB). 625:
4 Narrow Bands centered at 1MHz, 2MHz,
5MHz, & broadband 1.5–15MHz.
635 &
638: 6 narrow bands centered
at 0.5, 1, 2.25, 5, 10 & 15 MHz. Broad
band at 2 to 22 MHz (-6dB) and 1 to 35
MHz (-20dB).
Vertical Linearity:
1% full screen height.
Amplifier Linearity:
+/- 0.1 dB.
Horizontal Linearity:
+/- 0.4% full screen width (FSW).
Reject: 615
& 625 50% suppressive
reject. LED warning when selected. 635
& 638 80% linear reject.
Memory
Thickness Logging: Storage
for 8000 readings stored in Block/Location/Number
coding or alpha-numeric pre-programmed
work sheets. Transferable to Excel using
optional PC software.
Panel Memory:
100 storage locations for calibration
settings.
A-Scan Memory:
800 waveforms. |
Features
Wave Smoothing: Produces
a smooth signal envelope.
AGC: Automatic Gain
Control sets selected echo to a user defined
level (10 - 90%).
DAC: Up to 10 points
may be entered and used to digitally draw
a DAC curve. Reference -2, -6, -10, -12,
-14 dB curves can be selected for JIS,
ASME and EN1714 codes.
AWS: Automatic defect
sizing in accordance with AWS D1.1 Structural
Welding Code.
API: Automatic defect
sizing in accordance with API 5UE.
AVG/DGS: Automatic defect
sizing using probe data. 10 probe data
sets can be stored.
TCG: 625,
635 & 638 Time corrected
gain. 40 dB dynamic range, 30 dB per microsecond,
up to 10 points for curve definition.
Auto-Cal: Provides Automatic
calibration with two echoes.
Reference Waveform:
Recalled waveform can be shown in a different
color to live waveform for direct comparision.
Display Freeze: Hold
current waveform on screen.
Peak Memory: For echodynamic
pattern determination.
Online Help: Instant
operator guidance on operation accessed
from direct key.
Language Support: Six
user selectable languages from: English,
German, French, Spanish, Dutch, Italian,
Russian, Polish, Czech, Finnish &
Hungarian. Others available on request.
Power Source
Battery: Lithium Ion
battery pack 14.4V, 5.0 Amp hrs. Minimum
11 hours use, typical 15 hours, indication
of battery charge. Recharge time 4 hours.
Charger: 100 - 240 VAC,
50 - 60Hz.
Connections
USB: For connection
to PC, keyboard and printer.
Outputs: Serial Interface,
composite video (NTSC & PAL), analog
output for amplitude and distance updated
at PRF rate. Transmitter sync output.
Transducer Connectors:
available with BNC or LEMO 1 connectors
(factory option).
Additional 638
Features
Interface trigger: Interface
gate locks to surface echo and eliminates
water path variation.
High Power Pulser:
450 volt boost.
Warranty: 2 year
limited |